Tx Spacing

(Trunking System, OBT Channel Assignment)

HGDefinitionMob%26Port.jpg

Selects the spacing (in kHz) between Transmit (Tx) frequencies for the current OBT - Channel Range. DotYellow.png The Tx Start Frequency and Tx End Frequency define the current transmit frequency range. This selection applies for the current Trunking System.

HGWorkflowNote.jpg

 

WFForward.png The (Tx End Frequency - Tx Start Frequency) range value must be evenly divisible by this channel spacing. This allows the range to be divided into an integer value to properly assign the Control Channel number.

HGWarning.jpg

 

This setting must exactly match the same Central Controller setting for Trunking System communications to be possible.

HGAccessedOnly.jpg

When the System Type field is set to "Type II", and

when the Type II Frequency Band field is set to a "VHF", "UHF1" or "UHF2" OBT - frequency band, and

when the radio is model / option capable.

GoArrow.jpg

Go to the OBT Channel Assignment Page